{"id":59493,"date":"2024-11-04T14:05:53","date_gmt":"2024-11-04T10:35:53","guid":{"rendered":"https:\/\/test.iiees.ac.ir\/?page_id=59493"},"modified":"2025-03-16T13:02:29","modified_gmt":"2025-03-16T09:32:29","slug":"strong-floor-and-reaction-wall","status":"publish","type":"page","link":"https:\/\/www.iiees.ac.ir\/en\/strong-floor-and-reaction-wall\/","title":{"rendered":"Strong Floor and Reaction Wall"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-page\" data-elementor-id=\"59493\" class=\"elementor elementor-59493\" data-elementor-post-type=\"page\">\n\t\t\t\t<div class=\"elementor-element elementor-element-bb297f1 e-flex e-con-boxed e-con e-parent\" data-id=\"bb297f1\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-983a635 e-con-full e-flex e-con e-child\" data-id=\"983a635\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-5fa5602 elementor-widget elementor-widget-theme-post-title elementor-page-title elementor-widget-heading\" data-id=\"5fa5602\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"theme-post-title.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">Strong Floor and Reaction Wall<\/h1>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5d79099 elementor-mobile-align-left elementor-widget elementor-widget-post-info\" data-id=\"5d79099\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"post-info.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<ul class=\"elementor-inline-items elementor-icon-list-items elementor-post-info\">\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item elementor-repeater-item-0b1056d elementor-inline-item\" itemprop=\"datePublished\">\n\t\t\t\t\t\t<a href=\"https:\/\/www.iiees.ac.ir\/en\/2024\/11\/04\/\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-far-calendar-alt\" viewBox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M148 288h-40c-6.6 0-12-5.4-12-12v-40c0-6.6 5.4-12 12-12h40c6.6 0 12 5.4 12 12v40c0 6.6-5.4 12-12 12zm108-12v-40c0-6.6-5.4-12-12-12h-40c-6.6 0-12 5.4-12 12v40c0 6.6 5.4 12 12 12h40c6.6 0 12-5.4 12-12zm96 0v-40c0-6.6-5.4-12-12-12h-40c-6.6 0-12 5.4-12 12v40c0 6.6 5.4 12 12 12h40c6.6 0 12-5.4 12-12zm-96 96v-40c0-6.6-5.4-12-12-12h-40c-6.6 0-12 5.4-12 12v40c0 6.6 5.4 12 12 12h40c6.6 0 12-5.4 12-12zm-96 0v-40c0-6.6-5.4-12-12-12h-40c-6.6 0-12 5.4-12 12v40c0 6.6 5.4 12 12 12h40c6.6 0 12-5.4 12-12zm192 0v-40c0-6.6-5.4-12-12-12h-40c-6.6 0-12 5.4-12 12v40c0 6.6 5.4 12 12 12h40c6.6 0 12-5.4 12-12zm96-260v352c0 26.5-21.5 48-48 48H48c-26.5 0-48-21.5-48-48V112c0-26.5 21.5-48 48-48h48V12c0-6.6 5.4-12 12-12h40c6.6 0 12 5.4 12 12v52h128V12c0-6.6 5.4-12 12-12h40c6.6 0 12 5.4 12 12v52h48c26.5 0 48 21.5 48 48zm-48 346V160H48v298c0 3.3 2.7 6 6 6h340c3.3 0 6-2.7 6-6z\"><\/path><\/svg>\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text elementor-post-info__item elementor-post-info__item--type-date\">\n\t\t\t\t\t\t\t\t\t\t<time>November 4, 2024<\/time>\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t<\/li>\n\t\t\t\t<li class=\"elementor-icon-list-item elementor-repeater-item-a845ab1 elementor-inline-item\">\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-far-clock\" viewBox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8zm0 448c-110.5 0-200-89.5-200-200S145.5 56 256 56s200 89.5 200 200-89.5 200-200 200zm61.8-104.4l-84.9-61.7c-3.1-2.3-4.9-5.9-4.9-9.7V116c0-6.6 5.4-12 12-12h32c6.6 0 12 5.4 12 12v141.7l66.8 48.6c5.4 3.9 6.5 11.4 2.6 16.8L334.6 349c-3.9 5.3-11.4 6.5-16.8 2.6z\"><\/path><\/svg>\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text elementor-post-info__item elementor-post-info__item--type-time\">\n\t\t\t\t\t\t\t\t\t\t<time>2:05 pm<\/time>\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t<li class=\"elementor-icon-list-item elementor-repeater-item-58a234d elementor-inline-item\">\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-far-user-circle\" viewBox=\"0 0 496 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M248 104c-53 0-96 43-96 96s43 96 96 96 96-43 96-96-43-96-96-96zm0 144c-26.5 0-48-21.5-48-48s21.5-48 48-48 48 21.5 48 48-21.5 48-48 48zm0-240C111 8 0 119 0 256s111 248 248 248 248-111 248-248S385 8 248 8zm0 448c-49.7 0-95.1-18.3-130.1-48.4 14.9-23 40.4-38.6 69.6-39.5 20.8 6.4 40.6 9.6 60.5 9.6s39.7-3.1 60.5-9.6c29.2 1 54.7 16.5 69.6 39.5-35 30.1-80.4 48.4-130.1 48.4zm162.7-84.1c-24.4-31.4-62.1-51.9-105.1-51.9-10.2 0-26 9.6-57.6 9.6-31.5 0-47.4-9.6-57.6-9.6-42.9 0-80.6 20.5-105.1 51.9C61.9 339.2 48 299.2 48 256c0-110.3 89.7-200 200-200s200 89.7 200 200c0 43.2-13.9 83.2-37.3 115.9z\"><\/path><\/svg>\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text elementor-post-info__item elementor-post-info__item--type-custom\">\n\t\t\t\t\t\t\t\t\t\tDr. Mansour Ziaeifar\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3139b4d elementor-widget elementor-widget-text-editor\" data-id=\"3139b4d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p style=\"text-align: justify;\">The strong floor and reaction wall are among the most important components in structural laboratories for conducting tests on structural components and laboratory models of structures. Since research on scaled models of structures often involves serious ambiguities related to scaling effects, testing on large-scale models is usually required for important projects. In this regard, the International Institute of Seismology and Earthquake Engineering has designed and constructed large-scale strong floors and reaction walls to meet the country\u2019s needs for conducting large-scale tests on sensitive and important structures. The strong floor and reaction wall is built with the dimensions of 20\u00d730 meters and can perform multiple tests simultaneously.<\/p><p style=\"text-align: justify;\">The reaction wall in this facility is designed as two orthogonal walls connected to each other. Each of these walls is 15 meters long and 12 meters high, and they are connected to the strong floor. The strong floor and reaction wall is considered as a rigid support for horizontal and vertical actuators connected to the test specimen. The system is designed to simultaneously test a real-size four-story building in two horizontal directions under the effect of large earthquakes. Using this support system testing on structural models of taller and larger buildings is also possible (e.g. at 1\/2 and 1\/4 scales).<\/p><p style=\"text-align: justify;\">The strong floor and reaction wall can also be used for testing separate structural components such as beams, columns, walls, or substructures made from various materials at real-scale. This support system can also be used for testing industrial components, such as large aircraft wings, large wind turbine blades, and other large-scale components. Furthermore, it allows testing of oil rigs, offshore platforms, vessels, and mechanical parts related to dams and power plants.<\/p><p style=\"text-align: justify;\">The IIEES strong floor and reaction wall have several important features that distinguish it from other similar systems. One of these features is the use of a special type of clamp for connecting the specimen to the floor and wall, which allows faster and more accurate installation of specimens. This connection also enables the specimens to be firmly attached to the floor and wall with a fixed bearing connection rather than the typical frictional connections. This feature enhances the test set-ups by eliminating the possibility of sliding specimens on the connection surface during test.<\/p><p style=\"text-align: justify;\">Another feature of this strong floor and reaction wall is the routing of the hydraulic oil flow feeding the actuators outside the test area, behind the wall and under the strong floor, reducing the risks of oil leakage in the laboratory environment and the potential injury to the people in the lab. Furthermore, the majority of cables and wiring related to sensors, actuators, and the data recording system pass underneath the floor and behind the walls, improving workflow during the testing process.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-9542e0b e-con-full e-flex e-con e-child\" data-id=\"9542e0b\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;sticky&quot;:&quot;top&quot;,&quot;sticky_on&quot;:[&quot;widescreen&quot;,&quot;desktop&quot;,&quot;tablet&quot;],&quot;sticky_offset&quot;:100,&quot;sticky_effects_offset&quot;:1,&quot;sticky_parent&quot;:&quot;yes&quot;,&quot;sticky_anchor_link_offset&quot;:0}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-79933c4 elementor-widget elementor-widget-image\" data-id=\"79933c4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"https:\/\/www.iiees.ac.ir\/wp-content\/uploads\/2024\/11\/5.jpg\" data-elementor-open-lightbox=\"yes\" data-e-action-hash=\"#elementor-action%3Aaction%3Dlightbox%26settings%3DeyJpZCI6NTk0OTcsInVybCI6Imh0dHBzOlwvXC93d3cuaWllZXMuYWMuaXJcL2VuXC93cC1jb250ZW50XC91cGxvYWRzXC8yMDI0XC8xMVwvNS5qcGcifQ%3D%3D\">\n\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"800\" height=\"364\" src=\"https:\/\/www.iiees.ac.ir\/en\/wp-content\/uploads\/2024\/11\/5-1024x466.jpg\" class=\"attachment-large size-large wp-image-59497\" alt=\"\u06a9\u0641 \u0642\u0648\u06cc\" srcset=\"https:\/\/www.iiees.ac.ir\/en\/wp-content\/uploads\/2024\/11\/5-1024x466.jpg 1024w, https:\/\/www.iiees.ac.ir\/en\/wp-content\/uploads\/2024\/11\/5-300x137.jpg 300w, https:\/\/www.iiees.ac.ir\/en\/wp-content\/uploads\/2024\/11\/5-768x350.jpg 768w, https:\/\/www.iiees.ac.ir\/en\/wp-content\/uploads\/2024\/11\/5-600x273.jpg 600w, https:\/\/www.iiees.ac.ir\/en\/wp-content\/uploads\/2024\/11\/5.jpg 1030w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7dc914c elementor-widget elementor-widget-heading\" data-id=\"7dc914c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">(Image: Robabeh Zahedi)<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>The strong floor and reaction wall are among the most important components in structural laboratories for conducting tests on structural components and laboratory models of structures. Since research on scaled models of structures often involves serious ambiguities related to scaling effects, testing on large-scale models is usually required for important projects. In this regard, the [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"elementor_header_footer","meta":{"footnotes":""},"class_list":["post-59493","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.4 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Strong Floor and Reaction Wall - International Institute of Earthquake Engineering and Seismology<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.iiees.ac.ir\/en\/strong-floor-and-reaction-wall\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Strong Floor and Reaction Wall - International Institute of Earthquake Engineering and Seismology\" \/>\n<meta property=\"og:description\" content=\"The strong floor and reaction wall are among the most important components in structural laboratories for conducting tests on structural components and laboratory models of structures. Since research on scaled models of structures often involves serious ambiguities related to scaling effects, testing on large-scale models is usually required for important projects. In this regard, the [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.iiees.ac.ir\/en\/strong-floor-and-reaction-wall\/\" \/>\n<meta property=\"og:site_name\" content=\"International Institute of Earthquake Engineering and Seismology\" \/>\n<meta property=\"article:modified_time\" content=\"2025-03-16T09:32:29+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.iiees.ac.ir\/en\/wp-content\/uploads\/2024\/11\/5.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1030\" \/>\n\t<meta property=\"og:image:height\" content=\"469\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.iiees.ac.ir\\\/en\\\/strong-floor-and-reaction-wall\\\/\",\"url\":\"https:\\\/\\\/www.iiees.ac.ir\\\/en\\\/strong-floor-and-reaction-wall\\\/\",\"name\":\"Strong Floor and Reaction Wall - International Institute of Earthquake Engineering and Seismology\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.iiees.ac.ir\\\/en\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.iiees.ac.ir\\\/en\\\/strong-floor-and-reaction-wall\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.iiees.ac.ir\\\/en\\\/strong-floor-and-reaction-wall\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.iiees.ac.ir\\\/en\\\/wp-content\\\/uploads\\\/2024\\\/11\\\/5-1024x466.jpg\",\"datePublished\":\"2024-11-04T10:35:53+00:00\",\"dateModified\":\"2025-03-16T09:32:29+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.iiees.ac.ir\\\/en\\\/strong-floor-and-reaction-wall\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.iiees.ac.ir\\\/en\\\/strong-floor-and-reaction-wall\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.iiees.ac.ir\\\/en\\\/strong-floor-and-reaction-wall\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.iiees.ac.ir\\\/en\\\/wp-content\\\/uploads\\\/2024\\\/11\\\/5.jpg\",\"contentUrl\":\"https:\\\/\\\/www.iiees.ac.ir\\\/en\\\/wp-content\\\/uploads\\\/2024\\\/11\\\/5.jpg\",\"width\":1030,\"height\":469,\"caption\":\"\u06a9\u0641 \u0642\u0648\u06cc\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.iiees.ac.ir\\\/en\\\/strong-floor-and-reaction-wall\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.iiees.ac.ir\\\/en\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Strong Floor and Reaction Wall\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.iiees.ac.ir\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/www.iiees.ac.ir\\\/en\\\/\",\"name\":\"International Institute of Earthquake Engineering and Seismology\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.iiees.ac.ir\\\/en\\\/#organization\"},\"alternateName\":\"IIEES\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.iiees.ac.ir\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.iiees.ac.ir\\\/en\\\/#organization\",\"name\":\"International Institute of Earthquake Engineering and Seismology\",\"url\":\"https:\\\/\\\/www.iiees.ac.ir\\\/en\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.iiees.ac.ir\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.iiees.ac.ir\\\/en\\\/wp-content\\\/uploads\\\/2024\\\/06\\\/iiees-transparent5.png\",\"contentUrl\":\"https:\\\/\\\/www.iiees.ac.ir\\\/en\\\/wp-content\\\/uploads\\\/2024\\\/06\\\/iiees-transparent5.png\",\"width\":480,\"height\":82,\"caption\":\"International Institute of Earthquake Engineering and Seismology\"},\"image\":{\"@id\":\"https:\\\/\\\/www.iiees.ac.ir\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Strong Floor and Reaction Wall - International Institute of Earthquake Engineering and Seismology","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.iiees.ac.ir\/en\/strong-floor-and-reaction-wall\/","og_locale":"en_US","og_type":"article","og_title":"Strong Floor and Reaction Wall - International Institute of Earthquake Engineering and Seismology","og_description":"The strong floor and reaction wall are among the most important components in structural laboratories for conducting tests on structural components and laboratory models of structures. Since research on scaled models of structures often involves serious ambiguities related to scaling effects, testing on large-scale models is usually required for important projects. In this regard, the [&hellip;]","og_url":"https:\/\/www.iiees.ac.ir\/en\/strong-floor-and-reaction-wall\/","og_site_name":"International Institute of Earthquake Engineering and Seismology","article_modified_time":"2025-03-16T09:32:29+00:00","og_image":[{"width":1030,"height":469,"url":"https:\/\/www.iiees.ac.ir\/en\/wp-content\/uploads\/2024\/11\/5.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.iiees.ac.ir\/en\/strong-floor-and-reaction-wall\/","url":"https:\/\/www.iiees.ac.ir\/en\/strong-floor-and-reaction-wall\/","name":"Strong Floor and Reaction Wall - International Institute of Earthquake Engineering and Seismology","isPartOf":{"@id":"https:\/\/www.iiees.ac.ir\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.iiees.ac.ir\/en\/strong-floor-and-reaction-wall\/#primaryimage"},"image":{"@id":"https:\/\/www.iiees.ac.ir\/en\/strong-floor-and-reaction-wall\/#primaryimage"},"thumbnailUrl":"https:\/\/www.iiees.ac.ir\/en\/wp-content\/uploads\/2024\/11\/5-1024x466.jpg","datePublished":"2024-11-04T10:35:53+00:00","dateModified":"2025-03-16T09:32:29+00:00","breadcrumb":{"@id":"https:\/\/www.iiees.ac.ir\/en\/strong-floor-and-reaction-wall\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.iiees.ac.ir\/en\/strong-floor-and-reaction-wall\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.iiees.ac.ir\/en\/strong-floor-and-reaction-wall\/#primaryimage","url":"https:\/\/www.iiees.ac.ir\/en\/wp-content\/uploads\/2024\/11\/5.jpg","contentUrl":"https:\/\/www.iiees.ac.ir\/en\/wp-content\/uploads\/2024\/11\/5.jpg","width":1030,"height":469,"caption":"\u06a9\u0641 \u0642\u0648\u06cc"},{"@type":"BreadcrumbList","@id":"https:\/\/www.iiees.ac.ir\/en\/strong-floor-and-reaction-wall\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.iiees.ac.ir\/en\/"},{"@type":"ListItem","position":2,"name":"Strong Floor and Reaction Wall"}]},{"@type":"WebSite","@id":"https:\/\/www.iiees.ac.ir\/en\/#website","url":"https:\/\/www.iiees.ac.ir\/en\/","name":"International Institute of Earthquake Engineering and Seismology","description":"","publisher":{"@id":"https:\/\/www.iiees.ac.ir\/en\/#organization"},"alternateName":"IIEES","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.iiees.ac.ir\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.iiees.ac.ir\/en\/#organization","name":"International Institute of Earthquake Engineering and Seismology","url":"https:\/\/www.iiees.ac.ir\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.iiees.ac.ir\/en\/#\/schema\/logo\/image\/","url":"https:\/\/www.iiees.ac.ir\/en\/wp-content\/uploads\/2024\/06\/iiees-transparent5.png","contentUrl":"https:\/\/www.iiees.ac.ir\/en\/wp-content\/uploads\/2024\/06\/iiees-transparent5.png","width":480,"height":82,"caption":"International Institute of Earthquake Engineering and Seismology"},"image":{"@id":"https:\/\/www.iiees.ac.ir\/en\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/www.iiees.ac.ir\/en\/wp-json\/wp\/v2\/pages\/59493","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.iiees.ac.ir\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.iiees.ac.ir\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.iiees.ac.ir\/en\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.iiees.ac.ir\/en\/wp-json\/wp\/v2\/comments?post=59493"}],"version-history":[{"count":26,"href":"https:\/\/www.iiees.ac.ir\/en\/wp-json\/wp\/v2\/pages\/59493\/revisions"}],"predecessor-version":[{"id":63693,"href":"https:\/\/www.iiees.ac.ir\/en\/wp-json\/wp\/v2\/pages\/59493\/revisions\/63693"}],"wp:attachment":[{"href":"https:\/\/www.iiees.ac.ir\/en\/wp-json\/wp\/v2\/media?parent=59493"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}